5.3.3 Extra output
Optionally enable Wiegand or Magstripe output for tags that are not programmed by NEDAP in a Wiegand, Magstripe or
NEDAP-XS format.
'Protocol':
Disabled Do not use the extra output feature.
Wiegand Enable Wiegand output.
Magstripe Enable Magstripe output.
'Data source':
EPC number Output the EPC number using the selected protocol.
Custom read data Output the custom data read using the selected protocol.
See for more information about how to setup custom read data chapter 5.2.1.
'Alignment':
Full Use the complete EPC number (or all custom read data).
Left Truncate data. Keep left.
Right Truncate data. Keep right.
'Data length': Data length in bits for Wiegand (or in digits for Magstripe).
'Offset': Data offset in bits for Wiegand (or in digits for Magstripe).
'Add constant': Enable to add a constant to the output before or after the data read from the tag.
Example Wiegand 26
Output a Wiegand 26-bit message with facility code 10:
Figure 18: Extra output example 1