Control items Result
Connection – GND1
Connection–powercable,checktightness
Lightning conductor
Compressed air
Air lines cleaned
Air pressure (6–10 bar, 87–145 PSI)
Clean and dry air (ISO 8573-1, class 5)
Compressed air valve
Compressed air connected to unit
Ground check measurement
Check(≤100ohm):
GND1 – Fan
Check(≤10
5
ohm):
Incoming duct – Incoming mains ground
GND1 – External mains ground
Accessories (if applicable)
Signsandwarnings
Intended use marked or indicated
Safe bag replacement described or indicated
Initial start-up (function test)
Maintenanceswitch
Automaticstartandstop(standbyandresetswitch),iftted
Vacuumlimitingvalve(both,iftwoaretted)
Motor, direction of rotation
Time spent in Y mode
Automaticltercleaning
Manualltercleaning
Coveronthestartandcontrolunittted