EasyManua.ls Logo

Nederman E-PAK 500 - Page 37

Nederman E-PAK 500
392 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
E-PAK 500
37
EN
Appendix B: Service protocol
Copy the service protocol, ll it in and save it as a service record.
NOTE! If the results of the checks (for example, measured values) differ signicantly from
previous results, investigate more carefully.
E-PAK No. Date:
Operating hours:
Performed by:
Control items Result Result Result Result
Inspect/clean outside the unit
Removedustdeposits,cleanworkarea
Remove corrosion by grinding, apply primer and touch up paint
Inspect/clean inside the unit*
Powerconductorconnectionsandgroundwires,check
Automatic start and stop, check
Automaticltercleaning,check
Manualltercleaning,check
Vacuum limiting valve, check
(both,iftwoaretted)
Cleaning valve, check
Filter bags, visual check
Filter bags, check pressure drop/performance
Clean and dry air (ISO 8573-1, class 5), check
Groundmeasurement,check(≤100ohm):
GND1 – Fan
Groundmeasurement,check(≤10
5
ohm)
Incoming duct – Incoming mains ground
GND1 – External mains ground
Gaskets, check for leakage and replace, if necessary*
Mainlter,replace
Plastic bag, replace
*Whenreplacinglterbags.