FlexPAK 800/1000EN
12
3.1.8 Close Upper Slide Valve V12
The message appears when the TVFD Upper Solenoid Valve is expected to close. The
mer is set with TVFDC-Al, see Secon ‘4.2.26 TVFD-Al-Tmr. If the mer elapses, the
TVFD Alarm! Upper Slide Not Closed is acvated. This message is only shown when TVFD
advanced is acvated.
ESC OK
Close Upper
Slide Valve
Remaing me
08:00s
Remaining Time: The remaining me for the valve to close before the
alarm is acvated.
3.1.9 Emptying bin TVFD Advanced
The message appears when the TVFD Lower Solenoid Valve is expected to open. The mer
is set with TVFDC-Al, see Secon ‘4.2.26 TVFD-Al-Tmr. If the mer elapses, the ‘TVFD
Alarm! Lower Slide Not Open is acvated. This message is shown when TVFD advanced is
acvated. TVFD-Al is only acvated when using TVFD advanced.
ESC OK
EMPTYING BIN
Open Lower
Slide Valve
Remaing Time
02:00s
Remaining Time: The remaining me for the valve to open before the
alarm is acvated.
3.1.10 Close Lower Slide Valve V11
The message appears when the TVFD Lower Solenoid Valve is expected to close. The
mer is set with TVFDC-Al, see Secon ‘4.2.26 TVFD-Al-Tmr. If the mer elapses, the
TVFD Alarm! Lower Slide Not Closed is acvated. This message is only shown when TVFD
advanced is acvated.
ESC OK
Close Lower
Slide Valve
Remaing time
05:00s
Remaining Time: The remaining me for the valve to close before the
alarm is acvated.
3.1.11 Flushing duct
The unit is ushing the duct system. This message is shown when FlushCy1 and FlushCy2
acvate the ush valve. This message is also shown when FlushTemp is acvated, see
Secons ‘4.2.30 FlushCy1’, ‘4.2.22 FlushCy2’ and ‘4.2.24 FlushTmp’.
ESC OK
Flushing
Ducts
Cycl 1 03:00 s
Cycl 2 05:00 s
Cycl1: The me remaining for the ush cycle with the ush valve 1
(SFV1).
Cycl2: The me remaining for the ush cycle with the ush valve 2
(SFV2).

Table of Contents

Other manuals for Nederman FlexPAK 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nederman FlexPAK 800 and is the answer not in the manual?

Nederman FlexPAK 800 Specifications

General IconGeneral
BrandNederman
ModelFlexPAK 800
CategoryDust Collector
LanguageEnglish

Related product manuals