3.2.2 Warning! Main Filter Clogged
This Warning is only shown when the Main Filter Delta Pressure Switch (MFDPS) is
installed. This message is displayed if the Dierenal Pressure switch “DP switch” is
installed and the Dp switch detects a high dierenal pressure across the lter.
When the Dp switch detects a high Dp pressure, it acvates a mer, which is shown in the
display. If the Dp pressure is sll high when the mer elapses, the vacuum unit will stop and
the alarm message “Alarm! Main Filter Clogged” is acvated.
ESC OK
Warning!
Main Filter Clogged
Th 11:23
Time to Unit
Stop 08:00 m
Reset OK
Time to Unit Stop: Displays the me unl the unit is stopped.
3.2.3 Dustbin Full
The Bin Level Indicator has detected that the dust bin has been full for 12 minutes. Empty
the dust bin and press
OK
to reset the warning.
ESC OK
Warning!
D u s t b i n F u l l
Th 15:01
Time To Unit
Stop 05:00 m
Reset OK
Time to Unit Stop: Displays the me unl the unit is stopped.
3.2.4 Bag Replacement Switch Acvated
The bag replacement switch (SC2) is acvated. It shows the maximum allowed me to
replace the dust bag, and how much me is le to replace the dust bag and turn o the
bag replacement switch before the unit is put into O mode.
If this warning is acvated, the light in the Standby/Running buon is lit for two seconds
and then again in 2 seconds. This 2/2 on/o sequence connues unl the warning is reset.
ESC OK
Bag Replacement
Switch Activated
Time to Unit
Stop 02:00m
Max Time 30:00m
Stop: The remaining me to replace the dust bag before the unit is put
into O mode.
MaxTime: The maximum amount of me allowed to replace the dust
bag.
3.2.5 Warning Low Vacuum
Funcon to warn when the vacuum is too low in the system.
When the vacuum is too low, Vac_Low acvates the delay mer (VacLoTm) funcon when
the message expires. When the vacuum rises above the set limit value, the message
disappears automacally.
The Vac_Low parameter default seng is -15kPa.
The VacLoTm parameter default seng is 1 minute.
ESC OK
Warning Low
Vacuum
Limit 15kPa
Actual kPa 10kPa

Table of Contents

Other manuals for Nederman FlexPAK 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nederman FlexPAK 800 and is the answer not in the manual?

Nederman FlexPAK 800 Specifications

General IconGeneral
BrandNederman
ModelFlexPAK 800
CategoryDust Collector
LanguageEnglish

Related product manuals