FlexPAK 800/1000
23
EN
Weekend or second shi seng
ESC OK
WeekTmr 2/2
Off2 = -- : --
D3 = - - - - - - -
On3 = -- : --
Off3 = -- : --
Pulse = Off
D3 = _ _ _ _ _ SS: Default seng; Saturday and Sunday.
On3 = _ _: Default seng Time the unit set to ‘Stand By’ on chosen D3
days. Default seng is no preset me.
O3 = The me the unit is set to ‘O’ on chosen D3 days. Default seng
is no preset me.
Example
D3=_ _ _ _ _ SS Saturday, Sunday
On3 = 09:00 Unit starts at 9:00 in the morning Saturday, Sunday
O3 = 13:00 Unit Stops at 13:00 in the aernoon Saturday, Sunday
NOTE! Pulse = O: The pulse parameter must always be set to O.
NOTE! When the mer stops the unit and a valve at a workstaon is in its open posion,
the unit will start immediately once the mer puts the unit in standby mode.
It is not necessary to use the mer funcon. The funcon can be switched o by seng the
display to show only dashes. However, it is recommended that the mer funcon is used,
as this ensures that the unit is switched o even when a valve remains open, for example,
over night.
NOTE! If the weekly mer has been acvated, the amount of me the unit can be used
during the day before it automacally goes into O mode can be extended if the oponal
external standby buon accessory is used, see Secon ‘4.2.23 OTTmr.
4.2.3 H-Meter 1
Menu for seng the service interval. The default value is 2000 hours.
ESC OK
H-Meter 1/1
MI =2000h:0m
OT =0h:15m
MN =1999h:45
MN Ext =2000
MI =2000 hours: The amount of me between service intervals.
4.2.4 SSR_Time
Menu for seng the SSR mer. The SSR mer is for the amount of me before the unit
goes from Idling mode to Standby mode when the pilot signal disappears.
ESC OK
SSR_Time 1/1
T = 10:00m
Ta = 00:00
T=12:00 minutes: Time before SSR_Time is acvated. The default
seng is 12 minutes. The minimum seng is 5 minutes.
Ta=00:00 minutes: The elapsed me since the pilot signal disappeared.

Table of Contents

Other manuals for Nederman FlexPAK 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nederman FlexPAK 800 and is the answer not in the manual?

Nederman FlexPAK 800 Specifications

General IconGeneral
BrandNederman
ModelFlexPAK 800
CategoryDust Collector
LanguageEnglish

Related product manuals