FlexPAK 800/1000
23
EN
Weekend or second shi seng
ESC OK
WeekTmr 2/2
Off2 = -- : --
D3 = - - - - - - -
On3 = -- : --
Off3 = -- : --
Pulse = Off
D3 = _ _ _ _ _ SS: Default seng; Saturday and Sunday.
On3 = _ _: Default seng Time the unit set to ‘Stand By’ on chosen D3
days. Default seng is no preset me.
O3 = The me the unit is set to ‘O’ on chosen D3 days. Default seng
is no preset me.
Example
D3=_ _ _ _ _ SS Saturday, Sunday
On3 = 09:00 Unit starts at 9:00 in the morning Saturday, Sunday
O3 = 13:00 Unit Stops at 13:00 in the aernoon Saturday, Sunday
NOTE! Pulse = O: The pulse parameter must always be set to O.
NOTE! When the mer stops the unit and a valve at a workstaon is in its open posion,
the unit will start immediately once the mer puts the unit in standby mode.
It is not necessary to use the mer funcon. The funcon can be switched o by seng the
display to show only dashes. However, it is recommended that the mer funcon is used,
as this ensures that the unit is switched o even when a valve remains open, for example,
over night.
NOTE! If the weekly mer has been acvated, the amount of me the unit can be used
during the day before it automacally goes into O mode can be extended if the oponal
external standby buon accessory is used, see Secon ‘4.2.23 OTTmr’.
4.2.3 H-Meter 1
Menu for seng the service interval. The default value is 2000 hours.
ESC OK
H-Meter 1/1
MI =2000h:0m
OT =0h:15m
MN =1999h:45
MN Ext =2000
MI =2000 hours: The amount of me between service intervals.
4.2.4 SSR_Time
Menu for seng the SSR mer. The SSR mer is for the amount of me before the unit
goes from Idling mode to Standby mode when the pilot signal disappears.
ESC OK
SSR_Time 1/1
T = 10:00m
Ta = 00:00
T=12:00 minutes: Time before SSR_Time is acvated. The default
seng is 12 minutes. The minimum seng is 5 minutes.
Ta=00:00 minutes: The elapsed me since the pilot signal disappeared.