If there are mulple indicator lamps connected to the system, it is recommended that
semiconductor LED indicators used.
7 Pneumac lter cleaning valve
7.1 Filter cleaning buon
The lter cleaning buon will only work when the system is in Standby mode or Running
mode.
7.2 Filter cleaning in Standby mode
Perform a lter cleaning in Standby mode as follows:
1. From O mode, put the unit into Standby mode by pressing the Standby/Running
buon.
2. Start lter cleaning by pressing the lter cleaning buon.
The unit goes into Running mode, the motor starts and the FCV closes and vacuum is
established in the system. The unit will now open and close the FCV once and then leave
the FCV in its open posion. Aer the cleaning cycle, the unit goes into Idling mode. The
unit waits for a pilot signal for 10 minutes. If the pilot signal is not received during this me,
the unit will stop its motor and go into Standby mode.
To perform a new lter cleaning in Idling mode, acvate the pilot signal and enter Running
mode, or toggle the Standby/Running buon to go to Standby mode and press the lter
cleaning buon again.
7.3 Filter cleaning in Running mode
Perform lter cleaning in Running mode as follows:
1. Put the system into Standby mode by pressing the Standby/Running buon.
2. Acvate the pilot signal by connecng terminals X1:13 and X1:14 with a jumper.
The unit goes into Running mode. The motor starts, the FCV closes and pressure is
established in the system.
3. Start the lter cleaning by pressing the lter cleaning buon.
The unit will now open and close the FCV 3 mes and then leave the FCV in its closed
posion. Aer the last cleaning cycle, the unit returns to Running mode and waits for the
pilot signal to stop. It is possible to perform mulple lter cleaning cycles in Running mode.
When the pilot signal stops, the unit runs for 10 seconds (DIR me) and then opens the FCV
and goes into idling mode. The unit waits for a pilot signal for 12 minutes. If the pilot signal
is not received during this me, the unit will stop the motor and go into Standby mode.
The idling me is set by the SSR mer and default is 12 minutes. DIR me is the delay aer
the pilot signal has stopped before opening the FCV. The default is 10 seconds.
7.4 Filter cleaning valve funcon
The PLC output DO3 is set and sends +24 V to the solenoid valve. The solenoid valve opens
the air ow to the pneumac piston, which moves the lid on top of the lter upwards
leng in air with atmospheric pressure to the lter top. This sudden opening of the lid on
the top lets in air with great speed which creates a sudden pressure rise above the lters.
The pressure increase blows air through the lter bags removing the dust from the lters.
When power to the solenoid valve disappears, the valve closes and evacuates the
pneumac piston. The lid falls down and closes the opening of the lter top.