FlexPAK 800/1000
25
EN
4.2.9 Presep
Menu for acvang automac emptying of two preseparators. This cannot be used
together with TVFD. Presep acvates PresepTm to control the TVFD Solenoid Upper Valve
(SUV). It uses BinOpnTm to control the TVFD Solenoid Lower Valve (SLV).
ESC OK
Presep 1/1
Switch = Off
Switch=O is the default seng; Presep is deacvated and TFVD is
acvated.
To acvate Presep, set Switch=On.
4.2.10 MFDPS-Wr
Menu for seng the Main Filter Dierenal Pressure Sensor Warning (MFDPS-Wr) delay
mer. When the Main Filter Dierenal Pressure Sensor signal disappears, MFDPS-Wr is
acvated, and the delay mer has expired, the Main Filter Clogged warning message is
acvated. See Secon ‘3.2.2 Warning! Main Filter Clogged’.
ESC OK
MFDPS-Wr 1/1
T = 00:08m
Ta = 00:00m
T=10:00m Time before MFDPS-Wr is acvated. The default is 10
minute.
Ta=00:00 The elapsed me since the MFDPS signal disappeared.
4.2.11 MFDPS-FC
Menu for seng the Main Filter Dierenal Pressure Sensor Filter Cleaning (MFDPS-FC)
delay mer. When the Main Filter Dierenal Pressure Sensor signal disappears, MFDPS-
FC is acvated, and the delay mer for MFDPS-FC has expired, it acvates automac lter
cleaning if DPFClean is acvated, see Secon ‘4.2.40 DPFClean’. If PSIFC is set to ‘On’, the
lter cleaning sequence will not be acvated
ESC OK
MFDPS-FC 1/1
T = 01:00m
Ta = 00:00m
T=01:00m: Time before MFDPS-FC is acvated. The default seng is 1
minute.
Ta=00:00: The elapsed me since the MFDPS signal disappeared.
4.2.12 BLI-Empt
Menu for seng the BLI emptying delay me for the bin level indicator. This funcon is
only available when LiAuto is set to ‘On’, see secon ‘4.2.20 LiAuto’.
When the BLI signal disappears, the BLI-Empt delay mer is acvated, when the mer
elapses, the mer acvates the dust bin emptying sequence with either the AEB - Flap
Valve, simple TVFD, Advance TVFD or Preseparator.
If AEB-TVFD is set to ‘On’ , in other words, the AEB-Flap Valve is chosen, the bin emptying
sequence is interlocked when PSIFC is set to ‘On’. See Secon ‘4.2.32 PSIFC.
ESC OK
BLI-Empt 1/1
T = 10:00s
Ta = 00:00s
T=10:00m: Time before BLI-Empt is acvated. The default is 30 minutes.
Ta=00:00: The elapsed me since the BLI-Wr warning message was
acvated.

Table of Contents

Other manuals for Nederman FlexPAK 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nederman FlexPAK 800 and is the answer not in the manual?

Nederman FlexPAK 800 Specifications

General IconGeneral
BrandNederman
ModelFlexPAK 800
CategoryDust Collector
LanguageEnglish

Related product manuals