FlexPAK 800/1000
25
EN
4.2.9 Presep
Menu for acvang automac emptying of two preseparators. This cannot be used
together with TVFD. Presep acvates PresepTm to control the TVFD Solenoid Upper Valve
(SUV). It uses BinOpnTm to control the TVFD Solenoid Lower Valve (SLV).
ESC OK
Presep 1/1
Switch = Off
Switch=O is the default seng; Presep is deacvated and TFVD is
acvated.
To acvate Presep, set Switch=On.
4.2.10 MFDPS-Wr
Menu for seng the Main Filter Dierenal Pressure Sensor Warning (MFDPS-Wr) delay
mer. When the Main Filter Dierenal Pressure Sensor signal disappears, MFDPS-Wr is
acvated, and the delay mer has expired, the Main Filter Clogged warning message is
acvated. See Secon ‘3.2.2 Warning! Main Filter Clogged’.
ESC OK
MFDPS-Wr 1/1
T = 00:08m
Ta = 00:00m
T=10:00m Time before MFDPS-Wr is acvated. The default is 10
minute.
Ta=00:00 The elapsed me since the MFDPS signal disappeared.
4.2.11 MFDPS-FC
Menu for seng the Main Filter Dierenal Pressure Sensor Filter Cleaning (MFDPS-FC)
delay mer. When the Main Filter Dierenal Pressure Sensor signal disappears, MFDPS-
FC is acvated, and the delay mer for MFDPS-FC has expired, it acvates automac lter
cleaning if DPFClean is acvated, see Secon ‘4.2.40 DPFClean’. If PSIFC is set to ‘On’, the
lter cleaning sequence will not be acvated
ESC OK
MFDPS-FC 1/1
T = 01:00m
Ta = 00:00m
T=01:00m: Time before MFDPS-FC is acvated. The default seng is 1
minute.
Ta=00:00: The elapsed me since the MFDPS signal disappeared.
4.2.12 BLI-Empt
Menu for seng the BLI emptying delay me for the bin level indicator. This funcon is
only available when LiAuto is set to ‘On’, see secon ‘4.2.20 LiAuto’.
When the BLI signal disappears, the BLI-Empt delay mer is acvated, when the mer
elapses, the mer acvates the dust bin emptying sequence with either the AEB - Flap
Valve, simple TVFD, Advance TVFD or Preseparator.
If AEB-TVFD is set to ‘On’ , in other words, the AEB-Flap Valve is chosen, the bin emptying
sequence is interlocked when PSIFC is set to ‘On’. See Secon ‘4.2.32 PSIFC’.
ESC OK
BLI-Empt 1/1
T = 10:00s
Ta = 00:00s
T=10:00m: Time before BLI-Empt is acvated. The default is 30 minutes.
Ta=00:00: The elapsed me since the BLI-Wr warning message was
acvated.