OperATION
Home mode allows you to Arm selected zones
while others are ignored. Typically, perimeter
zones (doors and windows) can be monitored
while you are at home.
Your installer must program which zones will be
active in Home mode.
If an alarm occurs while in Home mode, entering
[uSer cOde]+ will silence the alarm. This
will also Disarm the panel, so remember to arm
Home Mode again if needed.
Using the optional Radio Keys you can enter
Home Mode by pressing either the OFF button
or the ON button twice within 4 seconds or
by pressing the AUX button, (RK4 radio key
only). These options must be enabled by your
installer.
Notes on Home Mode and Areas.
Home Mode can be used if the panel is fully
disarmed or if only Area2 is armed. Home mode
is not available when Area 1 is armed.
The panel can be armed in Home Mode if Area2
is already armed on these conditions:
• Area 1 must be OFF.
Area 2 must be armed first, and then Home
armed – not the reverse.
Zones assigned to both Home Mode and
to Area 2 will act as Home zones when both
Area 2 and Home Mode are armed.
Note: Home Mode arming when AREA 2 is
armed cannot be done by Radio Key or by
keyswitch.
To arm HOME Mode
by KEYPAD
by RADIO KEY
Press +
(If the hOme mOde ShOrtcut is enabled).
Home mode arming by radio key must be
enabled by your installer.
Press either the OFF
button or the ON button
twice within 4 seconds.
Or press the AUX
button once. (RK4
radio key only, if
enabled).
Or press +[User Code]+
The strobe light will flash briefly.
If required, your installer can program the
external siren to chirp twice when arming
Home mode.

Other manuals for Ness ECO8x

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ness ECO8x and is the answer not in the manual?

Ness ECO8x Specifications

Power IconPower
plug pack voltage240 V AC
plug pack output voltage17 V AC
plug pack output current1.4 A
power supply voltage13.8 V DC
power supply current800 mA
Battery IconBattery
battery voltage12 V
battery capacity7.0 Ah
battery charging current350 mA
Inputs and Outputs IconInputs and Outputs
zone inputs8
end of line resistor2200 Ohms
maximum keypads3
Weight and Dimensions IconWeight and Dimensions
box width235 mm
box height300 mm
box depth90 mm