20
Ness Guardpost Installation & Programming
PROGRAMMING OPTIONS
LOKOUT ALARM LOCKOUT
Sub-menu
ON Enabled
OFF Disabled (DEFAULT)
Alarm lockout prevents multiple sirens sounding due to an alarm from the same device. The external
siren will not sound again until the system is disarmed with the Disarm/Unlock button. The internal siren
will always sound unless the lockout option is on and then the internal siren will behave like an external
siren.
ENTRY ENTRY DELAY TIME
Entry delay time applies to
all enrolled devices.
Sub-menu
5 SEC (DEFAULT)
10 SEC
15 SEC
20 SEC
25 SEC
30 SEC
Entry Delay Time allows time to disarm the system once a detector is activated. Guardpost is normally
armed/disarmed by radio keys from outside the protected area but in some situations you may want to
disarm from inside the premises.
EXIT EXIT DELAY TIME
Exit delay time applies to all
enrolled devices.
Sub-menu
5 SEC (DEFAULT)
to 60 SEC in 5 second steps
Exit Delay Time allows time to exit the premises once the system is armed. All radio devices are inactive
during Exit Delay.
SIREN SIREN RUN TIME
Sub-menu
1 MIN
2 MIN
3 MIN
4 MIN
5 MIN (DEFAULT)
Sets the run time in minutes for the internal and optional external siren (if tted).
CHIRPS EXTERNAL SIREN CHIRPS
External Siren
ARMING: 1 Chirp
DISARMING: 3 Chirps
Sub-menu
ON Enabled (DEFAULT)
OFF Disabled
This option enables arm/disarm chirps for the external siren. External Siren Chirp applies only to
Arming/Disarming. HOME or HOME 2 modes never chirp.
V-ARM VOICE ANNUNCIATION FOR ARMING/DISARMING
When V-ARM is disabled
the internal speaker will
chirp on arming and
disaming.
Internal Siren
ARMING: 1 Chirp
DISARMING: 3 Chirps
Sub-menu
ON Enabled (DEFAULT)
OFF Disabled
This option enables voice annunciation of Arrming and Disarming.