21
Ness Guardpost Installation & Programming
PROGRAMMING OPTIONS
V-ALRM VOICE ANNUNCIATION FOR ALARMS
Sub-menu
ON Enabled (DEFAULT)
OFF Disabled
This option enables voice annunciation of Alarm events.
V-BATT VOICE ANNUNCIATION FOR BATTERY ALARMS
Sub-menu
ON Enabled (DEFAULT)
OFF Disabled
This option enables voice annunciation of low battery events.
V-FALT VOICE ANNUNCIATION FOR SYSTEM FAULTS
Sub-menu
ON Enabled (DEFAULT)
OFF Disabled
This option enables voice annunciation of system faults.
V-DEMO DEMONSTRATION MODE
Sub-menu
ON Enabled
OFF Disabled (DEFAULT)
Not available in this version.
OPEN OPEN/CLOSE REPORTS
Applicable when using
central station, Audible or
SMS monitoring.
Sub-menu
OFF All disabled (DEFAULT)
ON Open/Close Reports enabled (sent at end of exit delay)
RESTOR Alarm Restores enabled
RES+OC Alarm Restores and Open/Close Reports enabled
Open and Close reporting options.
LOWBAT LOW BATTERY REPORTING
Applicable when using
central station, Audible or
SMS monitoring.
Sub-menu
NONE No low battery reporting (DEFAULT)
MAIN Report low main battery
SENSOR Report low detector batteries (including Fixed Panic Buttons)
ALL Report low main unit and detector batteries
Low Battery reporting options.
CLIENT CLIENT ACCOUNT NUMBER
Applicable when using
central station monitoring.
Four digit client account
number.
Allowable range.
0000-FFFF
Digits can be hexadecimal,
but ‘A’ is not allowed for
protocol compatibility.
• Press ON to view the programmed client account number. The rst digit will ash.
• Press ON to step through values for the rst digit.
• Press PANIC to store the digit. The second digit will now ash.
• Repeat for the remaining digits.
• Press PANIC to store the last digit, and rst digit will ash.
• Repeat programming procedure to make corrections, or press OFF to return to top level