Configure System Information
47
Smart Managed Pro Switches MS510TX and MS510TXPP
• Select the port.
7. From the Auto Power Down Mode menu, select Enable or Disable.
The default is Disable, which is the global setting (see Configure the Global PoE Settings
on page 53). For ports g1–g4 only, you can disable the mode.
8. From the Short Cable Mode menu, select Enable or Disable.
The default is Disable, which is the global setting (see Configure the Global PoE Settings
on page 53). For ports g1–g4 only, you can disable the mode.
9. From the EEE Mode menu, select Enable or Disable.
The default is Disable. If the EEE mode is not supported, then N/A is displayed.
10. Click the Apply button.
Your settings are saved.
Configure Green Ethernet Settings for Local Devices
Use this page to configure and view detailed per-port green Ethernet settings for local
devices.
To configure and view green Ethernet for local devices:
1. Connect your computer to the same network as the switch.
You can use a WiFi or wired connection to connect your computer to the network, or
connect directly to a switch that is off-network using an Ethernet cable.
2. Launch a web browser.
3. In the address field of your web browser, enter the IP address of the switch.
If you do not know the IP address of the switch, see Access the Switch on page 12.
The login window opens.
4. Enter the switch’s password in the Password field.
The default password is password.
The System Information page displays.
5. Select System > Management > Green Ethernet > Green Ethernet Details.
The Local Device Information page displays.
6. From the Interface menu, select the interface.
7. To disable the Energy Detect Admin Mode for port g1, g2, g3, or g4, from the Energy
Detect Admin Mode, select Disable.
The Energy Detect Admin Mode is enabled globally, but you can disable it for ports g1–g4
only. With this mode enabled, the port transitions to low power mode during a link idle
condition.
The Operational Status field shows whether the energy detect operational status is active
or inactive.