Model H1301 Recovery and Recycling System
Installation, Operation and Maintenance Manual
Revision-L September, 2019
Page 33 of 105
V. System Operations and Controls
D. Automatic System Operation (continued)
8. If required adjust the Inlet Pressure Switch per source container application refer to
section-V.C: Inlet Pressure Switch Function and Adjustment.
9. Install the AGENT source container containing the Agent to be processed to the Inlet
port of the machine per section-IV. G: Source Container Installation.
WARNING! A method must be employed to restrain Agent source containers.
Uncontrolled discharge of pressurized containers will provide high
velocity container recoil resulting in Property Damage, Personal Injury or
Death.
WARNING! Do Not Connect AGENT or Nitrogen in excess of 600 psig to the Inlet
Port of the machine. Damage to the Machine, May Result.
NOTE: The source container must be configured to present a liquid discharge into the
machine. Discharge from the vapor side of a container containing liquid will result in
processing times 3 to 10 times longer than liquid discharge processing times.
10. Allow the machine to cool until the System Ready Lamp of the front panel illuminates.
11. Open the outlet valve of the source container.
12. Open the Manual Inlet Valve of the Machine.
13. Depress and release the Start Button of the front panel. The machine will immediately
begin to process the source Agent. The processing and inlet lamps of the front panel
will illuminate and after a short delay liquid should be visible in the moisture indicator
sight glass.
CAUTION: To avoid increased processing time and possible damage to the vapor
compressor of the machine: 1. DO NOT process source containers that are
below room temperature. 2. Maintain position of source containers to
provide complete liquid transfer before loss of nitrogen propellant into the
machine. 3. NEVER introduce liquid AGENT into the machine whenever
the front panel Evacuation lamp is illuminated. 4. NEVER place the inlet
compressor switch of the machine front panel into the on position during
automatic processing or whenever liquid is being introduced into the
machine unless directed to do so by this manual.