Control
FIGHTER 1120
50
Menu 7.3.10 Return
Pressing the enter button returns you to menu 7.3.0
Return
7.3.10
Clock
Menu 7.4.0 Temp set back time 2
Settings, e.g. for night reduction can be selected in the
sub-menus to this menu.
Temp set back time 2
7.4.0
Menu 7.4.1 Heating sys per. 2
The shunt system to be affected by day change period
2 is selected here. When shunt group 2 is installed,
both Shunt 1 and 2 can be selected.
Heating sys per. 2
7.4.1
Menu 7.4.2 Set back temp. +/-
Changes to the room temperature with a day change,
e.g. the night reduction is set here. The value is
adjustable between -10 and +10.
0
Set back temp. +/-
7.4.2
Menu 7.4.10 Return
Pressing the enter button returns you to menu 7.4.0
Return
7.4.10
U
U
Menu 7.4.3 - 7.4.9 Set Time Monday - Sunday
The time for the day change, e.g. night reduction is
chosen here.
Set Time Monday
7.4.3
U
U
Menu 7.5.0 Timer XHW
Settings are made in the sub-menus of this menu
when extra hot water is required on a specific day.
Timer XHW
7.5.0
Menu 7.5.2 - 7.5.8 Extra HW Monday - Sunday
Here you select the period for respective days when
extra hot water should be activated. Hours and min-
utes for both start and stop are shown. Equal values
or the stop time before the start time mean that extra
hot water is not activated.
03:30–06:15
Extra HW Monday
7.5.2
Menu 7.5.9 Return
Pressing the enter button returns you to menu 7.4.0
Return
7.5.9
Menu 7.8 Return
Pressing the enter button returns you to menu 7.0.
Return
7.8
U
U
Menu 7.5.1 Timer Extra HW
You choose here whether the time setting should be
On or Off.
Off
Timer Extra HW
7.5.1
U
Menu 7.7 Reset time settings
You can choose here to reset the time settings. Auto-
matic return to “Off” after one minute.
Off
Reset timers
7.7