Service menus
FIGHTER 1120
56
Operating settings
Menu 9.2.13.7 Return
Pressing the enter button returns you to menu 9.2.13
Return
9.2.13.7
Menu 9.2.13.5 Start value OilPower
In this menu you can set the number of degree min-
utes when the oil addition should start to work. Applies
to docking option 3.
The value is adjustable between -30 and -500
-400
Start value OilPower
9.2.13.5
S
Menu 9.2.13.6 Oil burner on
In this menu you set the running time for the oil burn-
er.
The value can be set between 0 and 12 hours.
12 h
Oil burner on
9.2.13.6
S
Quick start
Menu 9.4.1.26 Return
Pressing the enter button returns you to menu 9.4.0.
Return
9.4.1.26
Menu 9.3 Quick start
When “Yes” is selected, the heat pump starts within 5
minutes. Returns automatically to “No”, which indi-
cates that quick start is activated.
No
Quick start
9.3
S
TEST Force driven operation
Menu 9.4.0 TEST/Forced operat.
Test of outputs, automatic return after 30 minutes.
Only for service personnel.
TEST/Forced operat.
9.4.0
S
Menu 9.4.1.0 Forced operation
Selectable between “On” or “Off”.
Off
Forced operation
9.4.1.0
S
Menu 9.4.1.1 - 9.4.1.25
Manual test of relays, opto and AD.
RE1
9.4.1.1
S
Menu 9.2.15 RCU Present
No function.
Off
RCU Present
9.2.15
S
Menu 9.2.17 Return
Pressing the enter button returns you to menu 9.2.0
Return
9.2.17
Menu 9.2.14 Factory setting
Return to the factory settings in FIGHTER 1120, “Yes”
or “No”. When returning to the factory settings the lan-
guage switches to English.
No
Factory setting
9.2.14
S
Menu 9.2.16 Cooling system
Here you select whether HPAC or PKM is installed.
Off
Cooling system
9.2.16
S