Control
FIGHTER 1220
For the Installer
32
Brine flow/return
Menu 5.6 Number of starts
The accumulated number of starts with the compres-
sor is shown here.
82
Number of starts
5.6
U
Menu 5.9 Comp. acc. run time
The accumulated time that the compressor has been
in operation is shown here.
112h
Comp. acc. run time
5.9
U
Menu 5.11 Hot gas temp.
The hot gas temperature is shown in this menu.
104°C
Hot gas temp.
5.11
U
Menu 5.12 Liquide line Temp.
The fluid line temperature is shown in this menu.
48.2°C
Liquide line Temp.
5.12
U
Menu 5.13 Bulb temperature
The suction gas temperature is shown in this
menu.
55°C
Bulb temperature
5.13
U
Menu 5.14 Compressor type
No function.
Normal
Compressor type
5.14
U
Menu 5.21 Return
Pressing the enter button returns you to menu 5.0.
Return
5.21
Menu 7.1 Date
The current date is set.
Menu 7.3.0 Day change period 1
Settings, e.g. for night reduction can be selected in the
submenus to this menu.
2003-09-24
Date
7.1
Temp set back time 1
7.3.0
Menu 7.3.1 Heating sys per. 1
The shunt system to be affected by day change period
1 is selected here. When shunt group 2 is installed
both Shunt 1 and 2 can be selected.
Off
Heating sys per. 1
7.3.1
Menu 7.3.2 Set back temp. +/-
Changes to the flow temperature with a day change,
e.g. night reduction are set here. The value is
adjustable between -10 and 10.
0
Set back temp. +/-
7.3.2
Menu 7.2 Time
Here the current time is set.
13:39
Time
7.2
Clock
U
U
Menu 7.3.3 — 7.3.9 Set Time Monday — Sunday
The time for the day change, e.g. night reduction, is
chosen here.
Set Time Monday
7.3.3
U
N
N
U