Service menus
37
For the Installer
FIGHTER 1220
Operating settings
Menu 9.2.5 System 2 Present
This menu is used to select On or Off depending on
whether you have shunt group 2 (accessories needed).
Off
System 2 Present
9.2.5
Menu 9.2.6 Room disp Present
No function
Off
Room disp Present
9.2.6
S
S
Menu 9.2.4 Electric boiler
Electric boiler mode is activated when On is shown on
the display, otherwise Off is shown. When the electric
boiler mode is activated the immersion heater respec-
tive circulation pump cannot be blocked with the oper-
ating mode button. Select Off to deactivate electric
boiler mode and select the required operating mode
using the operating mode button.
Off
Electric boiler
9.2.4
S
Menu 9.2.7 Circ. pump 1
You choose here whether circulation pump 1 should
run constantly. The value is adjustable On or Off.
Off
Circ. pump 1
9.2.7
S
Menu 9.2.8 Circ. pump 2
You choose here whether circulation pump 2 should
run constantly. The value is adjustable On or Off.
Off
Circ. pump 2
9.2.8
S
Menu 9.2.9.0 Floor drying set
Settings for the floor drying program are made in the
submenus to this menu.
Floor drying set
9.2.9.0
S
Menu 9.2.9.1 Floor drying
The floor drying program is chosen from this sub-
menu. The options are Prog 1 On, Prog 2 On or Off
The heat pump must be in Winter mode, selected with
the operating mode button. Electric boiler mode, Menu
9.2.4 can be used together with floor drying, for exam-
ple, when the heat source is not installed.
In Prog 1 On, menus 9.2.9.2 9.2.9.5 are shown.
After time period 1 switching to time period 2 then
return to normal settings.
In Prog 2 On, a fixed program over 11 days follows.
The flow temperature is increased from 20°C to 45°C
for 4 days, it then remains constant for 3 days. The
temperature then steps down to 25°C for 4 days, and
then returns to the normal settings.
Off
Floor drying
9.2.9.1
Menu 9.2.9.2 Numb. of days per. 1
Selection of the number of days in period 1.
The value is adjustable between 1 to 5.
3
Numb. of days per. 1
9.2.9.2
Menu 9.2.9.3 Temp. period 1
Selection of the flow temperature in period 1.
The value is adjustable between 15 and 50°C.
25°C
Temp. period 1
9.2.9.3
S
S
S
Menu 9.2.9.4 Numb. of days per. 2
Selection of the number of days in period 2.
The value is adjustable between 1 to 5.
1
Numb. of days per. 2
9.2.9.4
Menu 9.2.9.5 Temp. period 2
Selection of the flow temperature in period 2.
The value is adjustable between 15 and 50°C.
40°C
Temp. period 2
9.2.9.5