15 – English
English
9.10.2 - Flashing light signals
Table 8.
TABLE 8
Flashes (quick) Status Action
1 second pause
ECSBus error At the beginning of the manoeuvre the devices present do not match those reco -
1 second pause
Intervention of a photocell
check to see if there are any obstructions.
1 second pause activated
1 second pause
Intervention of the Stop input
identify the cause
1 second pause
Error in the internal parameters of
the electronic control unit means there is a serious malfunction and the electronic board must be replaced
1 second pause
The maximum manoeuvre limit per
hour has been exceeded
Wait a few minutes until the manoeuvre limiting device drops below the maximum
limit
1 second pause
Error in the internal electric circuits Disconnect all the power circuits for a few seconds and then try giving a command
-
tronic board has to be replaced
1 second pause
A command that does not allow
other commands to be executed is
already present
Check the type of command that is always present (for example, it may be a com -
mand from a clock on the SbS input)
1 second pause
The automation is locked Release the automation by sending an automation release command to the con -
trol unit
9.10.3 - Control unit signals
On the control unit there are LEDs (Fig. 8 ) see Table 9.
TABLE 9
Led ECSBus Status Action
O Fault -
tify the reason for the failure then replace them with others of the same type
On Serious fault
condition persists, it means that there is a malfunction and the electronic circuit
board has to be replaced
Control unit works correctly
Input status variation
of photocells or the radio transmitter is used
(after a brief delay)
-
rated by a pause
Flashing light signal see Table 7 An overload has been detected therefore the power to the ECSBus was switched
o. To verify, disconnect one device at a time.
ECSBus short-circuit To activate power to the ECSBus, simply give a command (for example, through
the transmitter)
Stop led Status Action
O * Intervention of the Stop input Check the devices connected to the Stop input
On Stop input active
SbS led Status Action
O OPEN input not active
On Intervention of the SbS input Normal only if the device connected to the SbS input is actually active
L4 led Status Action
O * No Memorisation in progress
On Memorisation in Mode 1 During memorisation in Mode 1, it is normal for it to last maximum 10 seconds.
A series of quick Memorisation in Mode 2 During memorisation in Mode 2, it is normal for it to last maximum 10 seconds.
Successful deletion of a transmitter
Incorrect command A command has been received from a non-memorised transmitter
Memorisation completed successfully
Deletion of all transmitters completed successfully