32 – ENGLISH
TECHNICAL SPECIFICATIONS
12
12 TECHNICAL SPECIFICATIONS
l
All technical specications stated in this section refer to an ambient temperature of 20°C (± 5°C). Nice S.p.A.
reserves the right to apply modications to the product at any time when deemed necessary, without altering
its functions and intended use.
Table 15
TECHNICAL SPECIFICATIONS
Description Technical specication
S4-BAR - S4-BARI
Product type
Boom gate for residential use inclusive of electronic control unit
Clear opening (m)
4
Start peak torque (Nm)
100
Start peak torque (Nm)
25
Opening time (sec)
≥4 – >5 (with the XBA4 accessory)
Maximum frequency of
operating cycles/hour (at
nominal torque)
100 – 80 (with the XBA4 accessory)
Durability Refer to the “Product durability” paragraph
Power supply 230VC 50/60Hz
Power supply voltage /V1 230VC 50/60Hz
Maximum power draw at peak
(W)
300
Maximum power at nominal
torque (W)
200
Insulation class
1
Emergency power supply
With optional accessory PS124
Photovoltaic power supply
With optional accessory SYKCE
FLASH output
For 1 ELB ashing signalling light (12 V, 21 W lamp)
Courtesy light with optional accessories LED warning light XBA7
BLUEBUS output
One output with maximum load of 12 BlueBus units
STOP input
For normally closed or normally open contacts or for 8.2 kΩ xed resistor contacts with self-learning
(any variation from the memorised status triggers the STOP command)
Sbs input
For normally open contacts
OPEN input
For normally open contacts
CLOSE input
For normally open contacts
HP SbS input
For normally open contacts
Radio connector
SM connector for SMXI and SMXIS receivers
Radio ANTENNA input
50 Ω for RG58-type cable or similar
Programmable functions
Refer to the “PROGRAMMING” chapter and additional settings via the Oview Programming and
Control Unit
Self-learning functions
Self-learning of the devices connected to the BlueBus output
Self-learning of the type of “STOP” device (Normally Open, Normally Closed contact or 8.2 kΩ
resistor)
Learning of the door opening and closing positions
Operating temperature
-20°C ÷ 50°C
Use in highly acid, saline
or potentially explosive
atmosphere
No
Protection rating
IP44
Dimensions and weight
330x179,5x1146h mm; 35 kg