Testing to Environmental Category ENV3
Subjected to resonance search in the range listed. If no natural frequencies found then subjected only to endurance test.
Referenced standard: Environment Category ENV3:
Frequency range: 5 to 13.2 Hz ± 1.0 mm
13.2 to 100 Hz ± 0.7 g (6.9 ms -2)
For more information, please refer to section 12 Vibration Test 1 of the Lloyds Register Test Specification Number 1.