Commander S100 User Guide 55
7.2 Single line parameter descriptions
The lists below contain all parameters within the drive and states the possible settings of the parameter with the default value. For further description
of the parameters refer to section 7.3 Parameter descriptions or use the Marshal app.
7.2.1 Menu 1 - Status & monitoring (Read-only)
The lists in this table are for reference only and do not include sufficient information for adjusting these parameters. Incorrect
adjustment can affect the safety of the system and damage the drive and or external equipment. Before attempting to adjust any
of these parameters, refer to section 7.3 Parameter descriptions.
Parameter
Range
P1.01 Output Frequency ± Maximum Frequency Reference (P2.02) Hz
P1.02 Output Voltage
0 to Maximum Output Voltage V
(110 V, 200 V Drive = 240 V, 400 V Drive = 480 V)
P1.03 Output Power Drive Rating Dependent kW
P1.04 Motor RPM ±18000 rpm
P1.05 Drive State
Inhibited (0), Ready (1), NA (2), NA (3), Running (4), Supply Loss (5), Deceleration (6), Injecting DC (7),
NA (8), Error (9), NA (10), NA (11), NA (12), NA (13), NA (14), Under Voltage (15)
P1.06 Output Current ± Drive Rated Current x 2.2 A
P1.07 Torque Producing Current ± Drive Rated Current x 2.2 A
P1.08 Percentage Load ± Torque Current Maximum Limit %
P1.09 Alarm Indicators 00000000 to 11111111
P1.10 Drive Status Indicators 00000000 to 11111111
P1.11 Sequencer Input and Output Indicators 00000000 to 11111111
P1.12 Run & Direction Indicators 00000000 to 11111111
P1.13 Ramp Input ± Maximum Frequency Reference (P2.02) Hz
P1.14 Ramp Output ± Maximum Frequency Reference (P2.02) Hz
P1.15 T2 Analog Input 1 Percentage ±100.00 %
P1.16 T4 Analog Input 2 Percentage ±100.00 %
P1.17 T15 Frequency Input Percentage ±100.00 %
P1.18 Up/Down Percentage 0.0 to 100.0 %
P1.19 PID Output Percentage ±100.00 %
P1.20 PID Status Indicators 00000000 to 11111111
P1.21 PID Error ±100.00 %
P1.22 Motor Thermal Percentage 0 to 100 %
P1.23 Drive Thermal Percentage 0 to 100 %
P1.24 DC Bus Voltage
0 to Maximum D.C. Bus Voltage V
(110 V, 200 V Drive = 415 V, 400 V Drive = 830 V)
P1.25 Digital IO Indicators 00000000 to 11111111
P1.26 Parameter 1 Saved Value on Error Dependent on parameter saved
P1.27 Parameter 2 Saved Value on Error Dependent on parameter saved
P1.28 Parameter 3 Saved Value on Error Dependent on parameter saved
P1.29 Error 0to255
P1.30 Error History 1 0to255
P1.31 Error History 2 0to255
P1.32 Error History 3 0to255
P1.33 Drive Diagnostic 0to17