Safety
information
Product
information
Mechanical
installation
Electrical
installation
Getting
started
Running the
motor
Drive
parameters
Communications Diagnostics
Technical data
UL Listing
Information
108 Commander S100 User Guide
10 Technical data
This chapter covers additional technical data relating to the drive. This includes:
• Drive deratings for 4 kHz and 12 kHz switching frequency for standard and increased ambient temperatures
• Drive losses (Power dissipation)
• Drive storage
• Emission compliance for switching frequency and motor cable length cross reference
• Maximum cable lengths for 12 kHz switching frequency
• Miscellaneous drive data
• IP rating description
• Vibration test specification
Table 10-1 Environment specifications
1
See section 10.3 Drive storage
2
See section 10.1.2 Altitude
10.1 Drive derating
The drive output current must be derated when the drive is used in a suboptimal environment such as a higher altitude, increased ambient
temperature, reduced drive clearance, or if an increased switching frequency is used. The maximum continuous output current deratings in the
following tables should be used.
If a drive is to be mounted in a sealed enclosure with no air flow (<2 m/s) over the drive, select an operating temperature 5 °C above the measured
maximum internal temperature.
10.1.1 Temperature
Table 10-2 Maximum permissible continuous output current
Specification Detail
Storage temperature
-40 °C to 60 °C (-40 °F to 140 °F)
1
Operating temperature without derate
-10 °C to 40 °C (14 °F to 104 °F)
Operating temperature with derate
-10 °C to 60 °C (14 °F to 140 °F)
Altitude
≤3000 m (1000 m to 3000 m derate 1 % over 100 m)
2
Humidity
95 % non-condensing at 40 °C / 104 °F - EN61800-2(3k3)
Pollution
Pollution degree 2 - Dry, non-conducting pollution only
IP Rating
IP20
Vibration
Tested to IEC 60068-2-6
Corrosive Environments
Concentrations of corrosive gases must not exceed the levels given in: EN 60721-3-3 ISO9223 Class
C3
Drive Model Number
Nominal Power
Rating
Maximum continuous
output current @ 40
o
C
Maximum continuous
output current @ 50
o
C
Maximum continuous
output current @ 60 °C
kW hp
4 kHz 12 kHz 4 kHz 12 kHz 4 kHz 12 kHz
AAAAAA
100 V Drive (100 to 120 V ±10 %)
S100-01113 0.18 0.25 1.2 1 1 1 1.8 1.8
S100-01123 0.25 0.33 1.4 1.2 1.2 1.2 1 1
S100-01133 0.37 0.5 2.2 1.4 1.4 1.4 1.2 1.2
S100-03113 0.55 0.75 3.2 2.2 2.2 1.6 1.4 1.4
S100-03123 0.75 1 4.2 3.2 3.2 2.2 2.2 2.2
S100-03133 1.1 1.5 6 4.2 4.2 3.2 3.2 3.2