5.7 Restoring parameter defaults
Restoring parameter defaults by this method saves the default values in the drive memory.
Procedure via Keypad
1. Ensure the drive is not running. (Display shows: inh or rdy)
2. Set Restore Factory Defaults (P4.01) to 1 to load 50 Hz defaults; or 2 to load 60 Hz defaults.
3. Press or hold the settings button to exit the parameter and default the drive parameters.
Procedure via Marshal
1. Ensure the drive is not running.
2. Open Marshal and Connect to the drive to enter the Drive Dashboard.
3. Open the Project Menu tool bar and select default drive .
4. Follow on-screen instructions.
Procedure via Communications
1. Ensure the drive is not running.
2. Set Restore Factory Defaults (P4.01) to 1 to load 50 Hz defaults; or 2 to load 60 Hz defaults.
5.8 Drive security
Set Security PIN (P4.02) to a value between 1 and 9999 to prevent unauthorized parameter changes to occur.
If Security PIN (P4.02) is set to a value other than 0, when trying to access a writable parameter chosen in Parameter Select, ‘- - - -‘ will be displayed,
as shown in Table 5-2. The PIN set in Security PIN (P4.02) will then have to entered one digit at a time, pressing the settings button to confirm
each digit before the parameter value can be edited or viewed.