10 Digitax HD M75X Series Installation and Technical Guide
Issue Number: 5
2.4 Ratings
2.4.1 Maximum ratings
The drive ratings given below are for maximum 40 °C (104 °F), 1000 m altitude and 8 kHz switching frequency. Derating is required for higher
switching frequencies, ambient temperature >40 °C (104 °F) and higher altitude. For further information, refer to Chapter 6 Technical data on
page 98.
Table 2-1 Maximum RFC-S mode ratings
In continuous applications, the maximum allowed power may override the maximum allowable current.
Model No. of input phases
Nominal current Peak current Typical continuous output power
AA kW
01200022 1 1.1 6.6 0.3
01200040 1 2.2 12.0 0.7
01200065 1 3.5 19.5 1.1
02200090 1 5.6 27.0 1.8
02200120 1 7.5 36.0 2.3
03200160 1 10.8 48.0 3.4
01200022 3 2.2 6.6 0.7
01200040 3 4.0 12.0 1.3
01200065 3 6.5 19.5 2.0
02200090 3 9.0 27.0 2.7
02200120 3 12.0 36.0 3.7
03200160 3 16.0 48.0 5.0
01400015 3 1.5 4.5 0.8
01400030 3 3.0 9.0 1.6
01400042 3 4.2 12.6 1.9
02400060 3 6.0 18.0 3.1
02400080 3 8.0 24.0 4.2
02400105 3 10.5 31.5 5.6
03400135 3 13.5 40.5 6.9
03400160 3 16.0 48.0 7.6
NOTE

Table of Contents

Related product manuals