EasyManua.ls Logo

Nikon D60 - Page 85

Nikon D60
91 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VBA21001-R.3753.A
- R4
   
-
logo_Q0650_forGraphic
071004_Gdesign_ito
Items Judgment standard Remarks
Standby / consumed
current
Main SW / OFF: 200μA or less (when inner battery is fully
charged)
Main SW / ON (Half-release timer: OFF): 200μA or less (when
inner battery is fully charged)
Main SW / ON (Half-release timer: ON): 200mA or less (when
no operations made)
Main SW / ON (TFT monitor ON): 300mA or less
Power source: 7.8V
Luminance: EV12
Lens:
18-55/3.5-5.6G
Oscilloscope:
measured by +
current probe
Operation time Lens scan
18-55/3.5-5.6G: 1700 ms or less
     
Release without memory card 
(18-55/3.5-5.6G): 195ms or less
     (between mirror up and down)
Power source:
7.8V+0.3Ω
Luminance: EV12
Oscilloscope:
measured by +
current probe
Consumption current
accumulated
Lens scan
18-55/3.5-5.6G: 850 mAs or less
     
Release without memory card 
(18-55/3.5-5.6G): 320mAs or less
     (between mirror up and down)
Clock accuracy
20±5℃)
Difference par month: ±90 seconds Wave clock
BC level Level 5: 5 lights up  Charge remaining: 70 100%
Level 4: 4 lights up  Charge remaining: 50 69%
Level 3: 3 lights up  Charge remaining: 35 49%
Level 2: 2 lights up  Charge remaining: 20 34%
Level 1: 1 light up  Charge remaining: 1 19%
Level 0: 1 light blinking Charge remaining: 0%
Check the level in
the LCD control
panel on top of
camera or TFT
battery information
Communication-
capable battery tool
Bulb battery life 1 hour and 40 minutes or more When battery is
fully charged
Clock
INC

Table of Contents