VBA21001-R.3753.A
- R4
・
-
logo_Q0650_forGraphic
071004_Gdesign_ito
Items Judgment standard Remarks
Standby / consumed
current
Main SW / OFF: 200μA or less (when inner battery is fully
charged)
Main SW / ON (Half-release timer: OFF): 200μA or less (when
inner battery is fully charged)
Main SW / ON (Half-release timer: ON): 200mA or less (when
no operations made)
Main SW / ON (TFT monitor ON): 300mA or less
Power source: 7.8V
Luminance: EV12
Lens:
18-55/3.5-5.6G
Oscilloscope:
measured by +
current probe
Operation time Lens scan
18-55/3.5-5.6G: 1700 ms or less
Release without memory card
(18-55/3.5-5.6G): 195ms or less
(between mirror up and down)
Power source:
7.8V+0.3Ω
Luminance: EV12
Oscilloscope:
measured by +
current probe
Consumption current
accumulated
Lens scan
18-55/3.5-5.6G: 850 mAs or less
Release without memory card
(18-55/3.5-5.6G): 320mAs or less
(between mirror up and down)
Clock accuracy
(20±5℃)
Difference par month: ±90 seconds Wave clock
BC level Level 5: 5 lights up Charge remaining: 70 ~ 100%
Level 4: 4 lights up Charge remaining: 50 ~ 69%
Level 3: 3 lights up Charge remaining: 35 ~ 49%
Level 2: 2 lights up Charge remaining: 20 ~ 34%
Level 1: 1 light up Charge remaining: 1 ~ 19%
Level 0: 1 light blinking Charge remaining: 0%
Check the level in
the LCD control
panel on top of
camera or TFT
battery information
Communication-
capable battery tool
Bulb battery life 1 hour and 40 minutes or more When battery is
fully charged
Clock