Chapter 2 Microscopy
15
Table 2.1 Items required for the microscopy
Microscopy Page Illuminator Revolving nosepiece Objective Other items required
BF microscopy
under the epi
illumination
p.16 to p.18 5 revo., 6 revo.,
7 revo.
• For EPI objectives with 5
revo., LU nosepiece
adapter M32-25 required
• For 6 or 7 revo., BD
objective unavailable
⎯
DF microscopy
under the epi
illumination
p.19 5 revo. only BD objective only
⎯
Simplified
polarization
microscopy
under the epi
illumination
p.20 5 revo., 6 revo., 7
revo.
• For EPI objectives with 5
revo., LU nosepiece
adapter M32-25 required
• For 6 or 7 revo., BD
objective unavailable
• MA2-PA/MA2-UPA
polarizer/analyzer unit
• For the sensitive color
polarization microscopy,
MA2-λP λ plate available
DIC microscopy
under the epi
illumination
p.21 to p.22 5 revo., 6 revo. LU EPI objectives or LU BD
objective only
• For EPI objectives with 5
revo., LU nosepiece
adapter M32-25 required
• BD objective unavailable
for 6 revo.
For 5 revo.:
• MA2-PA
polarizer/analyzer unit
• L-DIHC/L-DIC slider
(single NR method)
• For the sensitive color
polarization microscopy,
the MA2-λP λplate
available
For 6 revo.:
• MA2-UPA
polarizer/analyzer unit
• LV-DIHC/LV-DIC slider
(Senarmont method)
• For the sensitive color
polarization microscopy,
the MA2-λP λplate
available
Epi-fl
microscopy
p.22
LV-LH 50PC
Lamphouse or
C-HGFI/C-HGFIE
HG Precentered
Fiber Illuminator
5 revo., 6 revo., 7
revo.
LU EPI objectives or LU BD
objective only
• For EPI objectives with 5
revo., LU nosepiece
adapter M32-25 required
• For 6 or 7 revo., BD
objective unavailable
• MA2-FL fluorescent unit
BF microscopy
under the dia
illumination
p.23 to p.26 5 revo., 6 revo., 7
revo.
• For EPI objectives with 5
revo., LU nosepiece
adapter M32-25 required
• For 6 or 7 revo., BD
objective unavailable
⎯
Simplified
polarization
microscopy
under the dia
illumination
p.27
Supporting pillar
for dia-Illuminator
100W
(+ condenser,
D-LH/LC
Lamphouse, 12V
100W halogen
lamp)
5 revo., 6 revo., 7
revo.
• For EPI objectives with 5
revo., LU nosepiece
adapter M32-25 required
• For 6 or 7 revo., BD
objective unavailable
• T-P2 polarizer
• MA2-PA/MA2-UPA
polarizer/analyzer unit (for
6 revo., the D-DA analyzer
is also available)
• For the sensitive color
polarization microscopy,
TI-DIC λplate available
(for 6 revo., the D-LP
λplate is also available)