112Service Manual – SC5000 24 - Electrical System
8-E007 Bat. Ah limit reached
Description Charge amp-hour Limit reached. Algorithm dependent.
Setting
Conditions
When Monitored
Charging
Possible Causes
Initial Action
Troubleshooting Steps
• Charger output reduced due to high temperatures. Operate at lower ambient temperature
• Charger output reduced due to low AC voltages. Check AC voltage.
• Check for shorted or damaged cells.
• Poor battery health. Replace battery.
• Very deeply discharged battery. Retry charge.
• Poorly connected battery. Check connections.
• This error will automatically clear once the charger is reset by cycling DC or by loss of AC for over 10
minutes.
8-E008 Batt Temp Out of Range
Description Battery temperature out of range. Algorithm dependent.
Setting
Conditions
When Monitored
Charging
Possible Causes
Initial Action
Troubleshooting Steps
• Cool or warm batteries as needed.
• Check temperature sensor and connections.
• This error will automatically clear once the condition has been corrected.