114Service Manual – SC5000 24 - Electrical System
8-017 USB error
Description USB mount/unmount error
Setting
Conditions
When Monitored
Updating
Possible Causes
Initial Action
Troubleshooting Steps
Remove and re-insert the USB Drive.
Ensure the USB ash drive is properly formatted and is not corrupted.
Ensure the USB ash drive does not draw excessive current.
If the condition persists then remove AC and battery for minimum 30 seconds and retry charger.
8-019 Software Rev Incorrect
Description Hardware build does not support software version
Setting
Conditions
When Monitored
Updating
Possible Causes
The charger hardware does not support the new software version trying to be
programmed. Existing SW is left running.
Initial Action
Troubleshooting Steps
8-E020 Active algo not set
Description No active algorithm selected
Setting
Conditions
When Monitored
Charging
Possible Causes
Initial Action
Troubleshooting Steps
Reboot the machine, and plug the charger into facility power for 30 seconds. If the error persists,
replace the charger.

Table of Contents

Other manuals for Nilfisk-Advance Advance SC5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nilfisk-Advance Advance SC5000 and is the answer not in the manual?

Nilfisk-Advance Advance SC5000 Specifications

General IconGeneral
BrandNilfisk-Advance
ModelAdvance SC5000
CategoryScrubber
LanguageEnglish

Related product manuals