115Service Manual – SC5000 24 - Electrical System
8-E021 Active algo not set
Description High battery voltage while charging. Algorithm dependent – typically 2.8V/cell
Setting
Conditions
When Monitored
Charging
Possible Causes
Initial Action
Troubleshooting Steps
• When already full, some new batteries may exhibit this error. Cycle the batteries and see if it reoccurs.
• Check battery size and condition. Resistive batteries in poor condition may cause this. Some new
batteries if charged when already full will also cause this. Cycle the batteries a few times.
• Check the battery voltage and cable connections.
• This error will automatically clear once the condition has been corrected.
8-E022 Low battery voltage
Description Low battery voltage while charging. Algorithm dependent – typically 0.1V/cell
Setting
Conditions
When Monitored
Charging
Possible Causes
Initial Action
Troubleshooting Steps
• Another device may be drawing current from the battery.
• Check the battery voltage and cable connections.
• Check battery size and condition. Batteries may be over-discharged. Use another charger to bring the
batteries above the minimum voltage.