117Service Manual – SC5000 24 - Electrical System
8-026 USB Script Failed
Description One or more USB script commands failed
Setting
Conditions
When Monitored
Updating
Possible Causes
Initial Action
Troubleshooting Steps
Ensure the USB ash drive is properly formatted.
Ensure the right update package is being used.
Copy the install les to the USB ash drive again.
Retry the update by reinserting the USB Flash Drive into the charger.
8-027 USB overcurrent fault
Description USB overcurrent fault
Setting
Conditions
When Monitored
Updating
Possible Causes
Initial Action
Troubleshooting Steps
USB hardware overcurrent protection has been tripped. Remove and reinsert USB ash drive. If
condition persists, try using a different USB ash drive.
8-E028 Incompatible algo
Description Algorithm error
Setting
Conditions
When Monitored
Charging
Possible Causes
Initial Action
Troubleshooting Steps
Update charger software, continue to use existing algorithm or select a different charging algorithm that
is compatible.

Table of Contents

Other manuals for Nilfisk-Advance Advance SC5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nilfisk-Advance Advance SC5000 and is the answer not in the manual?

Nilfisk-Advance Advance SC5000 Specifications

General IconGeneral
BrandNilfisk-Advance
ModelAdvance SC5000
CategoryScrubber
LanguageEnglish

Related product manuals