Electrical System 75Service Manual – SC6500
To Charge the Batteries
1. Disconnect the machine battery connector.
2. Open the side access panel and push the connector from the charger into the battery connector.
3. Follow the instructions on the battery charger.
4. After charging the batteries, check the uid level in all battery cells. Add distilled water if necessary to
bring the uid level up to the bottom of the ller tubes.
Warning!
Do not fill the batteries before charging.
Charge the batteries in a well-ventilated area.
Do not smoke while servicing the batteries.
When Servicing Batteries
Remove all jewelry.
Do not smoke.
Wear safety glasses, rubber gloves and a rubber apron.
Work in a well-ventilated area.
Do not allow tools to touch more than one battery terminal at a time.
ALWAYS disconnect the negative (ground) cable rst when replacing batteries to prevent sparks.
ALWAYS connect the negative cable last when installing batteries.
Caution! To avoid damage to floor surfaces, wipe water and acid from the top of the batteries
after charging.