Dust Control System 47Service Manual – SW4000
Troubleshooting
Trouble Possible causes Remedy
Dust/debris vacuuming is insufcient The lter is clogged Clean the dust lter by using the lter shaker
or by disassembling it.
The vacuum system compartment gasket is
damaged
Repair/replace
No vacuuming The fuse (F1) is open. Replace the fuse.
The switch (SW3) is not efcient Replace
The relay (K1) is not efcient Replace
The vacuum system is broken Repair/replace
The lter shaker does not operate. The fuse (F2) is open. Replace the fuse.
The lter shaker is disconnected. Connect the lter shaker connector.
The switch (SW3) is not efcient Replace
The relay (K2) is not efcient Replace
The lter shaker is broken Repair/replace