ã2000 Nokia Mobile Phones. All Rights Reserved. 31
COLP information:
When the presentation of COLP on the DTE is enabled (and the
called subscriber permits), the +COLP:<number>,<type>[,,,<al-
pha>] response is returned before any +CR or V.25ter responses. Re-
fer to AT+CLIP for descriptions of the response parameters.
AT+CR Service Reporting Control
This command controls whether or not the result code +CR:<serv>
is returned from the data adapter to the computer. If enabled, the
result code is transmitted at the point during the connect negotia-
tion during which the data adapter has determined the speed and
quality of service to be used, before any error control or data com-
pression reports are transmitted, and before any final result code
(e.g. CONNECT) is transmitted.
Syntax:
AT+CR=[<mode>] Set service reporting control mode.
AT+CR? Query current setting. Response is +CR:
<mode>.
AT+CR=? Show supported values. Response is +CR: (0,1).
Parameters:
<mode>
0 disable reporting
1 enable reporting
<serv>
ASYNC asynchronous transparent
REL ASYNC asynchronous non-transparent