3. S-Registers
S-Reg Unless otherwise specified the value range
Default
of the settings is from 0 to 255
S0 Defines the number of rings after which the termi-
nal automatically answers the call (Auto Answer
Function). If the setting is 0, automatic answer is
disabled.
0
S1 Ring count (read only) 0
S2 Escape code character 43
S3 Carriage return character 13
S4 Line feed character 10
S5 Backspace character 8
S7 Wait for connection completion (seconds)
(0=connection waiting time is unlimited).
60
S8 Sets the duration, in seconds, for the pause (,)
option in the dial command.
2
S10 DCD OFF to hang-up delay (seconds/10). Setting
255 signifies that the connection will not be
cleared even if the DCD drops.
Default is 6 seconds.
100
S12 Escape Guard Time (seconds/50) 0=escape disabled. 50
S14 For changing the S14 settings, use the following AT
commands: ATEn (n=1) to enable the key presses to
be displayed on the screen or (n=0) to disable,
ATQn (n=0) to enable or (n=1) to disable the
responses,
ATVn to switch between the textual (long format)
responses
10