ã2000 Nokia Mobile Phones. All Rights Reserved. 33
AT+ILRR? Query current setting. Response is +ILRR:
<mode>.
AT+ILRR=? Show supported values. Response is +ILRR:
(0,1).
Values for <mode>:
0 local port rate reporting disabled
1 local port rate reporting enabled
2.6. Network Communication Parameter Commands
ATB Communications Standard Option
This command has no effect on the data adapter. It is included for
compatibility rea-
sons. Syntax:
ATB[<n>]
AT+CBST Select Bearer Service Type
This command selects the bearer service <name> with data rate
<speed> , and the connection element <ce> to be used when data
calls are originated. The selected bearer service, rate, and connec-
tion element are used both in mobile originated and mobile termi-
n a t e d d a t a a n d a l t e r n a t e t y p e o f c a l l s d u r i n g d a t a m o d e .
Syntax:
AT+CBST=[<speed>[,<name>[,<ce>]]]
Select bearer service type.
AT+CBST? Query current setting.
Response is +CBST: <speed>,
<name>, <ce>.
AT+CBST=? Show supported values.
Response is +CBST: (list of sup-
ported
<speed>s), (list

Table of Contents