5 Parameters
BU 0505 EN-3021 159
P731
Parameter set
(Actual parameter set)
0 ... 3 Shows the actual operating parameter set.
0 = Parameter set 1
1 = Parameter set 2
2 = Parameter set 3
3 = Parameter set 4
Pos: 410 /Anleitungen/ Elektronik/F U und Starter/5. Parameter/ Parameterauflis tung (P000 ...)/P700- P799/Parameter P732 – Stro m Phase U @ 0\mod_1328173601208 _388.docx @ 13077 @ @ 1
P732
Phase U current
(U phase current)
S
0.0 ... 999.9 A Displays the actual U phase current.
NOTE: This value can deviate somewhat from the value in P719, due to the measurement
procedure used, even with symmetrical output currents.
Pos: 411 /Anleitungen/ Elektronik/F U und Starter/5. Parameter/ Parameterauflis tung (P000 ...)/P700- P799/Parameter P733 – Stro m Phase V @ 0\mod_1328173830046 _388.docx @ 13100 @ @ 1
P733
Phase V current
(V phase current)
S
0.0 ... 999.9 A Displays the actual V phase current.
NOTE:
This value can deviate somewhat from the value in P719, due to the measurement procedure
used, even with symmetrical output currents.
Pos: 412 /Anleitungen/ Elektronik/F U und Starter/5. Parameter/ Parameterauflis tung (P000 ...)/P700- P799/Parameter P734 – Stro m Phase W @ 0\mod_1328173871579_ 388.docx @ 13123 @ @ 1
P734
Phase W current
(W phase current)
S
0.0 ... 999.9 A Displays the actual W phase current.
NOTE:
This value can deviate somewhat from the value in P719, due to the measurement procedure
used, even with symmetrical output currents.
Pos: 414 /Anleitungen/ Elektronik/F U und Starter/5. Parameter/ Parameterauflis tung (P000 ...)/P700-P799/Parameter P735 – Drehzahl Dreh geber [SK 54xE] @ 0\mod_13281 73990708_388.doc x @ 13169 @ @ 1
P735 [-01]
...
[-03]
Speed encoder
(Speed encoder)
S
-9999 ... 9999 rpm Displays the actual rotation speed supplied by the incremental encoder. P301 / P462 / P605 must
be correctly set according to the type of encoder.
[-01] = TTL Encoder
[-02] = HTL Encoder
[-03] = Absolute Encoder
Pos: 415 /Anleitungen/ Elektronik/F U und Starter/5. Parameter/ Parameterauflis tung (P000 ...)/P700- P799/Parameter P736 – Zwi schenkreisspannung @ 0\ mod_1328174969216_38 8.docx @ 13192 @ @ 1
P736
D.c. link voltage
(DC link voltage)
0 ... 1000 V DC Displays the actual link voltage.
Pos: 416 /Anleitungen/ Elektronik/F U und Starter/5. Parameter/ Parameterauflis tung (P000 ...)/P700- P799/Parameter P737 – Akt uelle Auslastung Brem swiderstand @ 0\mod_13281 75007763_388.doc x @ 13215 @ @ 1
P737
Usage rate brakeres.
(Actual brake resistor usage rate)
0 ... 1000 % This parameter provides information about the actual degree of modulation of the brake chopper
or the current utilisation of the braking resistor in generator mode.
If parameters P556 and P557 are correctly set, the utilisation related to P557, the resistor power,
is displayed.
If only P556 is correctly set (P557=0), the degree of modulation of the brake chopper is displayed.
Here, 100 means that the brake resistor is fully switche
d. On the other hand, 0 means that the
brake chopper is not active at present.
If P556 = 0 and P557 = 0, this parameter also provides information about the degree of
modulation of the brake chopper in the FI.
Pos: 417 /Anleitungen/ Elektronik/F U und Starter/5. Parameter/ Parameterauflis tung (P000 ...)/P700- P799/Parameter P738 – Akt uelle Auslastung Motor @ 0\ mod_1328175060231_388. docx @ 13238 @ @ 1