Page 142 of 488 Installing software on the CS 1000E
553-3041-210 Standard 4.00 September 2007
Verifying Call Server 0 is active
Use the following commands to verify that Call Server 0 is active.
Make the system redundant
At this point, Core/Net 0 is ready to be synchronized with Core/Net 1.
Procedure 28
Making the system redundant
1 Check to see if the LAN 1 and LAN 2 cables are attached. If not, attach
the LAN 1 and LAN 2 cables to the CP PIV faceplate connectors on Call
Server 0 and Call Server 1.
2 Once the synchronization of memories and drives is complete, STAT the
CPU and verify that the CPUs are in a true redundant state.
LD 135 Load program
STAT CPU Get the status of the CPUs
CFN
LD 135
STAT CPU Get status of CPU and memory
**** Exit the program