E. Generator Install Location
E.8 Use provided Generator Installation Bracket Floor Cut-out Template to
verify the metal mounting bracket was made correctly and holes and air intake and
air outflow areas are cut correctly. See Exhibits 5 and 16
E.9 Install Generator in a way which does not inhibit the removal of the Generator
Service Access Door for proper and routine operation and maintenance. See Exhibits 2
and 3
E.10 Generator and exhaust operate at a high temperature, therefore installation
of Generator shall not be in the same compartment or housing with any flammable
vapor, combustible material or ignition sources.
Page 20 of 55 Rev. 1