H. Exhaust Kit Installation
H.3 DANGER! GASOLINE and VAPORS are FLAMMABLE and EXPLOSIVE
Throughout the installation process:
• Keep multi-class ABC fire extinguishers within reach of installer and readily
available
• All rags soiled with gasoline or oil must be discarded in a fire-proof container
• Routinely check for leaks and collections of gasoline pooling in install area
• Secure and shield fuel lines separately and away from electrical wiring to prevent
accidental ignition
• Keep all ignition sources away from fuel lines and including:
o
open flames
o
arc producing equipment
o
sparks
o
pilot lights
o
electrical switches
• DO NOT smoke or permit others to smoke at or near install location
H.4 Use only the approved NPS Y6000eco exhaust kit for all NPS
Generator Model installations.
H.5 The generator exhaust system is engineered to prevent exhaust gases from
entering into the living area of the RV. It is critical that the clamps are secured
tightly to prevent gas vapors and CO from escaping prior to the outlet of the
exhaust. See Exhibits 6, 7, 8 and 9.
H.6 Determine what length of downpipe (included in the installation kit) is necessary to
extend the exhaust pipe to meet exhaust clearance requirements. Downpipe is shown in
Exhibit 6.
H.7 The use of the down-pipe will depend on Generator install location for specific
RV model applications.