I. Electrical Connection
Remote Start Panel Connection (continued)
I.28 At the Remote Start Panel:
• Connect the Generator Hours Meter Connector lock-clip (green and white wires
pre-installed on the Remote Start Panel) to the Remote Start Wiring Harness
corresponding lock-clip (brown and orange wires) See Exhibits 11 and 12.
• Connect the Remote Start Wiring Harness female spade connectors to the Remote
Start Panel male spade connectors. See Exhibit 12.
• Pair female and male spade connectors utilizing the Remote Start Panel Wiring
Harness Diagram. See Exhibit 12.
• Verify all Remote Start Panel Wiring Harness spade connectors are fully and
securely paired.
• Once Remote Start Panel Wiring Harness is connected to the Remote Start Panel
and pairing is verified, securely attach the Remote Start Panel to the RV interior
location as specified by the manufacturer for that RV model.
II.29 At the Generator:
• Locate the black female-end connector of the Remote Start Wiring Harness. See
Exhibit 11.
• Route the black female-end connector of the Remote Start Wiring Harness
through the rubber grommet, on the right side of the Generator (located above the
12Volt ground connection), from outside the Generator to inside. See Exhibit 10
and 14.
• Securely connect the black female-end connector to the black male-end located
inside the Service Access Door and connected by a pigtail to the Generator
control module. See Exhibit 11, 13 and 14.
Page 38 of 55 Rev. 1