UG8000-00 November 2002
Page 1-4
NV6064 SYSTEM DESCRIPTION
The NV6064 Universal Digital Router system is housed in a single frame, including
electronics and power supplies. The frame is 12 RUs high and designed to be installed
in a standard 19” equipment rack. In addition to those discussed on the previous
pages, features of the NV6064 include:
• Dual output connectors to reduce DA requirements.
• Optional redundant power supply.
• Optional secondary control available for some host controllers.
Front and rear panels are described starting below; NV6064 specifications follow the
rear panel description.
NV6064 Front Panel
Figure 1-2 illustrates the NV6064 front panel (door open). The front panel provides
access to the following assemblies:
X
Cooling fans, pull air into the frame through the front door and
exhaust air out through the rear.
Y
Up to 8 Output modules (can be a combination of SDI and
SWB) 8 outputs per board.
Z
Output Monitor module (optional).
[
Controller, Primary and Secondary (optional). Module is not slot
dependent.
\
Up to 8 Input modules (can be a combination of SDI and SWB),
8 inputs per board.
]
Main Crosspoint module slot, 64 inputs x 64 outputs.
^
Unused slot.
_
Main Power Supply.
`
Redundant Power Supply (optional).