Table continued from the previous page...
Field Function
4
SW_BANK_SEL
2
SW_BANK_SEL2
0: NOR flash bank select bit2 of switch status is 0.
1: NOR flash bank select bit2 of switch status is 1.
5
BANK_SEL0
BANK_SEL0
0: NOR flash bank select bit0 set 0.
1: NOR flash bank select bit0 set 1.
6
BANK_SEL1
BANK_SEL1
0: NOR flash bank select bit1 set 0.
1: NOR flash bank select bit1 set 1
7
BANK_SEL2
BANK_SEL2
0: NOR flash bank select bit2 set 0.
1: NOR flash bank select bit2 set 1.
3.1.8 Thermal control and status register (THMCSR)
Offset
Register Offset
THMCSR 12h
Diagram
Bits
0 1 2 3 4 5 6 7
R THM_FAU... THM_ALE...
Reserved FAN_PWM
W
Reset
u u 0 0 1 1 1 1
Fields
Field Function
0
THM_FAULT
THM_FAULT
0: Thermal sensor no fault occurs.
1: Thermal sensor fault output.
1 THM_ALERT
Table continues on the next page...
NXP Semiconductors
CPLD Specification
QorIQ T2080 Reference Design Board (T2080RDB-PC) User Guide, Rev. 1, 08/2021
User Guide 35 / 44