BA_OCHSNER AIR EAGLE_414_717_V06_EN.docx Page 30 of 76
5 Connection lines
5.1 Refrigerant lines
NOTE
If the appliance, the refrigerant lines,
the fixing points and the wall conduits
are not properly installed, structure-
borne sound may be transmitted to the
building.
➔ Ensure the refrigerant lines are
secured in a way to minimise
structure-borne sound. The system
installer carrying out the work is
responsible for this.
WARNING
Work on the refrigerant circuit may be
carried out only by an authorised and
suitably qualified contractor.
o When handling refrigerant, wear
appropriate gloves, protective
clothing and protective glasses.
Always position the outdoor unit as closely to the
indoor unit as possible. The maximum length of
the connection line must not exceed a total length
of 25.0 m! Do not exceed a maximum difference in
height of 15.0 m.