Loading...
BA_OCHSNER AIR EAGLE_414_717_V06_EN.docx Page 44 of 76
EAGLE 414 with T200 indoor unit
A
Main distributor
B
Indoor unit control box
C
Outdoor unit control box
1
Compressor supply
(C20A)
2
Controller supply
(C13A)
3
Electric booster heater supply
a: 3x 400 V (B16A across all
poles)
b: 1x 230 V (B40A)
3a
Booster heater with
3-phase power supply
3b
Booster heater with
single phase power supply
4
Option:
Supply for DHW auxiliary
heater for anti-legionella
function
5
Modbus cable
6
Control cable
7
Compressor supply
8
Option:
Mains switch for EAGLE out-
door unit

Table of Contents