Sensor Test
Value:
Should input wording ~ be displayed in the right cell?
Display in the right cell the wording in parentheses in ~ and the state of
each sensor (H/L). Examples of this display are shown below:
MEDIA H/L
SCAN H/L
REVERSE H/L
ADF CVR H/L
FB H/L
Display sensor status (H/L) in real time. Change the content of the display as
needed when the sensor status displayed changes.
Set-document detection sensor (MEDIA)
Scanning sensor (SCAN)
Reverse sensor (REVERSE)
ADF cover-open senor (ADF CVR)
FB home-position sensor (FB HP)
ADF Motor Test
Value:
Forward
Forward Continuous
Reverse
Reverse Continuous
Test the ADF motor
After a short press of the button, rotate in the CW direction for 10 seconds and
then stop.
After a long press of the button, rotate in the CW direction continuously. Stop
when the Stop button is pressed.
After a short press of the button, rotate in the CCW direction for 10 seconds
and then stop.
After a long press of the button, rotate in the CCW direction continuously.
Stop when the Stop button is pressed.
Deemed successful at all times. No need to display results.
Display "Testing" during execution?
Display a message on the panel showing that testing is underway