The displays are switched pressing [2].
BELT: A belt motor constant-speed timer value (a set input/output value)
(in hex).
FRM: Three asterisks in square brackets ([***]) identifies a read frame
thermistor AD value (in hex).
Three cross signs in brackets ((xxx)) identifies a frame temperature (in
Celsius).
The displays are switched pressing [2].
DB: A developing voltage setting table identification number (in hex).
The displays are switched pressing [2].
TR1: A transfer voltage parameter VTR1 table identification number (in
hex).
TR2: A transfer voltage parameter VTR2 table identification number (in
hex).
The displays are switched pressing [2].
TROFF: A transfer off voltage setting table identification number (in hex).
BELT: Three cross signs and a minus sign (xxx-) identifies a read belt
thermistor AD value (in hex).
Three asterisks and a minus sign (***-) identifies a belt temperature (in
hex).
5. Repeat steps 2 through 4 when necessary.
6. Press the [#] button to end the test (the state for step 1 is restored).