5. MAINTENANCE MENUS
Item1 Item2 Item3 Item4 Item5 Value
Default
value
ODA
Default
value
OEL
Default
value
JP
Notes
Password Scanner
Maintenance
Mechanical
Tes t
FBS Test Speed Color 300x300dpi
Color 300x600dpi
Color 600x600dpi
Mono
Conduct mechanical testing (without reading an image).
ADF : Test moving original document (stops when set document has been moved)
May choose from single- or double-sided feeding.
FBS : CIS moving test (stops after designated number of operations)
Use fastest read speed (40 cpm).
Display"Testing"duringexecution?
→
Onthepanel,indicatecurrentnumberofexecutionsusingthemessage"Testno.xxx
underway."
TImes 0~65535
Execute --results--
Test no. xxx underway
Sensor
Tes t
Examples of this display are
shown below:
①
MEDIA H/L
SCAN H/L
REVERSE H/L
ADF CVR H/L
FB H/L
Display sensor status (H/L) in real time. Change the content of the display as needed
when the sensor status displayed changes.
①
Set-document detection sensor (MEDIA)
②
Scanning sensor (SCAN)
③
Reverse sensor (REVERSE)
④
ADF cover-open senor (ADF CVR)
⑤
FB home-position sensor (FB HP)
ADF Motor
Tes t
Forward
Forward Continuous
Reverse
Reverse Continuous
Test the ADF motor
After a short press of the button, rotate in the CW direction for 10 seconds and then stop.
After a long press of the button, rotate in the CW direction continuously. Stop when the
Stop button is pressed.
After a short press of the button, rotate in the CCW direction for 10 seconds and then
stop.
After a long press of the button, rotate in the CCW direction continuously. Stop when the
Stop button is pressed.
Deemed successful at all times. No need to display results.
Display"Testing"duringexecution?
Display a message on the panel showing that testing is underway.
Solenoid
Tes t
Once
Continuous
After a short press of the button, intake for 2 seconds and then stop.
After a long press of the button, intake for 2 seconds and stop for 3 seconds repeat.
Stop when the Stop button is pressed.
Deemed successful at all times. No need to display results.
Display"Testing"duringexecution?
Display a message on the panel showing that testing is underway.