44952001TH Rev.2
5-9
Oki Data CONFIDENTIAL
5. MAINTENANCE MENUS
5.2 Service Bit Menu
Additional Fax Setting menu
(When setup ServiceBit=ON, the following items will be displayed at Admin Setup
Fax
Setup)
# Item Settings Description ODA OEL JP1
1 Tone For
Echo (For
Transmission)
Enable
Disable
When an Item is Enable:
First DIS is ignored. Echo Protection
Tone is sent with V.29. Interval of
DIS and DCS is 1000 ms.
When an Item is Disable:
First DIS is not ignored. Echo
Protection Tone is not sent with V.29.
Interval of DIS and DCS is 0 ms.
Disable Disable Disable
2 Tone For
Echo (For
Reception)
Enable
Disable
When an Item is Enable :
Interval of CED and DIS is 1000 ms.
When an Item is Disable :
Interval of CED and DIS is 75 ms.
Disable Disable Disable
3 Attenuator 0~15 dB Enter Attenuator. Depends on Country
Code
4 MF
Attenuator
0~15 dB Enter MF (Tone) Attenuator. Depends on Country
Code
5 Pulse Make
Ratio
33%
39%
40%
Sets the make rate of DP (10
pps) during call.
It only shows, when ServiceBit
= ON and Tone/Pulse setting =
PULSE.
Depends on Country
Code
6 Pulse Dial
Typ e
N
10-N
N+1
It only shows, when ServiceBit
= ON and Tone/Pulse setting =
PULSE.
Depends on Country
Code
7 MF(Tone)
Duration
75, 85, 100
mseconds
Enter MF (Tone) Duration.
It only shows, when ServiceBit
= ON and Tone/Pulse setting =
TONE.
Depends on Country
Code
# Item Settings Description ODA OEL JP1
8 Calling Timer 1~255 second
(s)
Sets the call connection wait
time (TO timer). When the setting
valueis"0",theMFPrunsat
the initial value of each country.
Whenanyvalueotherthan"0"is
set, the call connection wait time
(TO timer) can be selected in the
range of 1 to 255 mm.
Depends on Country
Code