Page #170 background imageLoading...
Page #170 background image
44952001TH Rev.2
5-23
Oki Data CONFIDENTIAL
5. MAINTENANCE MENUS
• Thefollowingmessageappearsduringprinting:
P=***
W=***
P: Number of test print pages
W: Wait time
• Thedisplaysareswitchedbypressing[2].
T=*** U=***[###]
H=***%L=***[###]
U: Three asterisks (***) identifies a measured upper heater temperature (in
Celsius). Three sharp signs in square brackets ([###]) identifies a target
print temperature (in Celsius).
L: Three asterisks (***) identifies a measured lower heater temperature (in
Celsius). Three sharp signs in square brackets ([###]) identifies a read
lower thermistor AD value (in hex).
T: A measured ambient temperature (in Celsius).
H: A measured ambient humidity (in percent figures).
• Thedisplaysareswitchedbypressing[2].
KTR=*.** YTR=*.**
MTR=*.** CTR=*.**
YTR, MTR, CTR and KTR indicate the set transfer voltage values for colors,
respectively (in kV).
• Thedisplaysareswitchedbypressing[2].
KR=*.** YR=*.**
MR=*.** CR=*.**
KR: A black transfer roller resistance value (in uA).
YR: A yellow transfer roller resistance value (in uA).
MR: A magenta transfer roller resistance value (in uA).
CR: A cyan transfer roller resistance value (in uA).
• Thedisplaysareswitchedbypressing[2].
ETMP=***UTMP=***
REG=****EXT=***
ETMP: A parameter for correction of constant hopping motor speed (an
ambient temperature) (in decimal).
UTMP: A parameter for correction of constant fuser motor speed (a target
fusing temperature) (in decimal).
REG: A hopping motor constant-speed timer value (a set input/output value)
(in hex).
EXT: A fuser motor constant-speed timer value (a set input/output value) (in
hex).
• Thedisplaysareswitchedtothefollowingbypressing[2].
ID=****
ID: An image drum motor constant-speed timer value (a set input/output
value) (in hex).
• Thedisplaysareswitchedpressing[2].
BELT=****
FRM [***] ( xxx )
BELT: A belt motor constant-speed timer value (a set input/output value) (in
hex).
FRM: Three asterisks in square brackets ([***]) identifies a read frame
thermistor AD value (in hex).
Three cross signs in brackets ((xxx)) identifies a frame temperature (in
Celsius).
• Thedisplaysareswitchedbypressing[2].
DB:k**y**m**c**
DB: A developing voltage setting table identification number (in hex).

Table of Contents

Other manuals for Oki MPS2731mc

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Oki MPS2731mc and is the answer not in the manual?

Oki MPS2731mc Specifications

General IconGeneral
BrandOki
ModelMPS2731mc
CategoryAll in One Printer
LanguageEnglish

Related product manuals