3K5
1-3-15
U411
Error Codes
Completion
Press the stop key. The screen for selecting a maintenance item is displayed.
Maintenance
item No.
Description
Codes Description
ERROR 01 Black band detection error (scanner leading edge registration)
ERROR 02 Black band detection error (scanner center line)
ERROR 03 Black band detection error (scanner main scanning direction magnification)
ERROR 04 Black band is not detected (scanner leading edge registration)
ERROR 05 Black band is not detected (scanner center line)
ERROR 06 Black band is not detected (scanner main scanning direction magnification)
ERROR 07 Black band is not detected (scanner auxiliary scanning direction magnification)
ERROR 08 Black band is not detected (DP main scanning direction magnification far end)
ERROR 09 Black band is not detected (DP main scanning direction magnification near end)
ERROR 0a Black band is not detected (DP auxiliary scanning direction magnification leading
edge)
ERROR 0b Black band is not detected (DP auxiliary scanning direction magnification leading
edge original check)
ERROR 0c Black band is not detected (DP auxiliary scanning direction trailing edge)
ERROR 0d Black band is not detected (DP auxiliary scanning direction trailing edge 2)
ERROR 0e DMA time out
ERROR 0f Auxiliary scanning direction magnification error
ERROR 10 Auxiliary scanning direction leading edge detection error
ERROR 11 Auxiliary scanning direction trailing edge detection error
ERROR 12 Auxiliary scanning direction skew 1.5 error
ERROR 13 Maintenance request error
ERROR 14 Main scanning direction center line error
ERROR 15 Main scanning direction skew 1.5 error
ERROR 16 Main scanning direction magnification error
ERROR 17 Carriage error
ERROR 18 Service call error
ERROR 19 DP status error
ERROR 1a DP open error
ERROR 1b Original is not detected
ERROR ff Other error
ERROR 65 Memory over error